Table 2

Coronary CTA data

Baseline (N = 154)Follow-up (N = 154)P-value
Total plaque volume (mm³)475 (173–902)514 (190–1030)<0.001
Calcified plaque volume (mm³)30 (10–70)74 (21–150)<0.001
Non-calcified plaque volume (mm³)420 (162–822)417 (179–784)0.030
Number of plaques4 (1–6)5 (2–7)<0.001
CAD scorea11 (5–19)14 (8–21)<0.001
Maximal stenosis in all segments
 No CAD14 (9)0 (0)N/A
 <30%59 (38)53 (34)0.34
 30–50%29 (19)54 (35)<0.001
 50–70%17 (11)21 (14)0.37
 70–90%26 (17)17 (11)0.020
 >90%8 (5)9 (6)0.71
 Uninterpretable1 (1)0 (0)N/A
Baseline (N = 154)Follow-up (N = 154)P-value
Total plaque volume (mm³)475 (173–902)514 (190–1030)<0.001
Calcified plaque volume (mm³)30 (10–70)74 (21–150)<0.001
Non-calcified plaque volume (mm³)420 (162–822)417 (179–784)0.030
Number of plaques4 (1–6)5 (2–7)<0.001
CAD scorea11 (5–19)14 (8–21)<0.001
Maximal stenosis in all segments
 No CAD14 (9)0 (0)N/A
 <30%59 (38)53 (34)0.34
 30–50%29 (19)54 (35)<0.001
 50–70%17 (11)21 (14)0.37
 70–90%26 (17)17 (11)0.020
 >90%8 (5)9 (6)0.71
 Uninterpretable1 (1)0 (0)N/A

Per-patient change in plaque characteristics between baseline and follow-up coronary CTA (n = 154). Values are presented as median (IQR) or n (%). Values in bold font indicate statistically significant results.

aBased on a comprehensive CTA score incorporating the presence, extent, severity, location, and composition of CAD.

N/A, not applicable.

Table 2

Coronary CTA data

Baseline (N = 154)Follow-up (N = 154)P-value
Total plaque volume (mm³)475 (173–902)514 (190–1030)<0.001
Calcified plaque volume (mm³)30 (10–70)74 (21–150)<0.001
Non-calcified plaque volume (mm³)420 (162–822)417 (179–784)0.030
Number of plaques4 (1–6)5 (2–7)<0.001
CAD scorea11 (5–19)14 (8–21)<0.001
Maximal stenosis in all segments
 No CAD14 (9)0 (0)N/A
 <30%59 (38)53 (34)0.34
 30–50%29 (19)54 (35)<0.001
 50–70%17 (11)21 (14)0.37
 70–90%26 (17)17 (11)0.020
 >90%8 (5)9 (6)0.71
 Uninterpretable1 (1)0 (0)N/A
Baseline (N = 154)Follow-up (N = 154)P-value
Total plaque volume (mm³)475 (173–902)514 (190–1030)<0.001
Calcified plaque volume (mm³)30 (10–70)74 (21–150)<0.001
Non-calcified plaque volume (mm³)420 (162–822)417 (179–784)0.030
Number of plaques4 (1–6)5 (2–7)<0.001
CAD scorea11 (5–19)14 (8–21)<0.001
Maximal stenosis in all segments
 No CAD14 (9)0 (0)N/A
 <30%59 (38)53 (34)0.34
 30–50%29 (19)54 (35)<0.001
 50–70%17 (11)21 (14)0.37
 70–90%26 (17)17 (11)0.020
 >90%8 (5)9 (6)0.71
 Uninterpretable1 (1)0 (0)N/A

Per-patient change in plaque characteristics between baseline and follow-up coronary CTA (n = 154). Values are presented as median (IQR) or n (%). Values in bold font indicate statistically significant results.

aBased on a comprehensive CTA score incorporating the presence, extent, severity, location, and composition of CAD.

N/A, not applicable.

Close
This Feature Is Available To Subscribers Only

Sign In or Create an Account

Close

This PDF is available to Subscribers Only

View Article Abstract & Purchase Options

For full access to this pdf, sign in to an existing account, or purchase an annual subscription.

Close