Correction value for first-generation HR-pQCTa–based ITSa analyses to true second-generation HR-pQCT value. HR-pQCT parameters plus correction value equal true value. Those parameters which were not shown in the table have significant linear relations in the Bland–Altman plots.
. | Radius . | Tibia . | ||
---|---|---|---|---|
. | Correction value . | P-value . | Correction value . | P-value . |
BV/TV | −0.037 | .27 | −0.038 | .82 |
pBV/BV | 0.366 | .98 | ||
rBV/BV | −0.366 | .98 | ||
pTb.N (1/mm) | 0.140 | .21 | 0.118 | .15 |
rTb.N (1/mm) | −0.242 | .50 | ||
pTb.Th (mm) | −0.011 | .51 | 0.000 | .15 |
rTb.l (mm) | 0.024 | .11 | ||
R-R Junc.D (1/mm3)a | −1.102 | .05 | ||
P-R Junc.D (1/mm3)a | 0.403 | .53 | ||
P-P Junc.D (1/mm3) | 0.493 | .89 |
. | Radius . | Tibia . | ||
---|---|---|---|---|
. | Correction value . | P-value . | Correction value . | P-value . |
BV/TV | −0.037 | .27 | −0.038 | .82 |
pBV/BV | 0.366 | .98 | ||
rBV/BV | −0.366 | .98 | ||
pTb.N (1/mm) | 0.140 | .21 | 0.118 | .15 |
rTb.N (1/mm) | −0.242 | .50 | ||
pTb.Th (mm) | −0.011 | .51 | 0.000 | .15 |
rTb.l (mm) | 0.024 | .11 | ||
R-R Junc.D (1/mm3)a | −1.102 | .05 | ||
P-R Junc.D (1/mm3)a | 0.403 | .53 | ||
P-P Junc.D (1/mm3) | 0.493 | .89 |
Abbreviation: aHR-pQCT, high-resolution peripheral quantitative computed tomography; ITS, individual trabecula segmentation; P-P Junc.D, plate-to-plate junction density; P-R Junc.D, plate-to-rod junction density; R-R Junc.D, rod-to-rod junction density.
Correction value for first-generation HR-pQCTa–based ITSa analyses to true second-generation HR-pQCT value. HR-pQCT parameters plus correction value equal true value. Those parameters which were not shown in the table have significant linear relations in the Bland–Altman plots.
. | Radius . | Tibia . | ||
---|---|---|---|---|
. | Correction value . | P-value . | Correction value . | P-value . |
BV/TV | −0.037 | .27 | −0.038 | .82 |
pBV/BV | 0.366 | .98 | ||
rBV/BV | −0.366 | .98 | ||
pTb.N (1/mm) | 0.140 | .21 | 0.118 | .15 |
rTb.N (1/mm) | −0.242 | .50 | ||
pTb.Th (mm) | −0.011 | .51 | 0.000 | .15 |
rTb.l (mm) | 0.024 | .11 | ||
R-R Junc.D (1/mm3)a | −1.102 | .05 | ||
P-R Junc.D (1/mm3)a | 0.403 | .53 | ||
P-P Junc.D (1/mm3) | 0.493 | .89 |
. | Radius . | Tibia . | ||
---|---|---|---|---|
. | Correction value . | P-value . | Correction value . | P-value . |
BV/TV | −0.037 | .27 | −0.038 | .82 |
pBV/BV | 0.366 | .98 | ||
rBV/BV | −0.366 | .98 | ||
pTb.N (1/mm) | 0.140 | .21 | 0.118 | .15 |
rTb.N (1/mm) | −0.242 | .50 | ||
pTb.Th (mm) | −0.011 | .51 | 0.000 | .15 |
rTb.l (mm) | 0.024 | .11 | ||
R-R Junc.D (1/mm3)a | −1.102 | .05 | ||
P-R Junc.D (1/mm3)a | 0.403 | .53 | ||
P-P Junc.D (1/mm3) | 0.493 | .89 |
Abbreviation: aHR-pQCT, high-resolution peripheral quantitative computed tomography; ITS, individual trabecula segmentation; P-P Junc.D, plate-to-plate junction density; P-R Junc.D, plate-to-rod junction density; R-R Junc.D, rod-to-rod junction density.
This PDF is available to Subscribers Only
View Article Abstract & Purchase OptionsFor full access to this pdf, sign in to an existing account, or purchase an annual subscription.