Journal Article

Ultrasound Measurement of Optic Nerve Sheath Diameter as Non-Invasive Detector of Raised Intracranial Pressure in Adult Traumatic and Non-Traumatic Neurocritical Patients in ICU

QJM: An International Journal of Medicine, Volume 117, Issue Supplement_2, October 2024, hcae175.042, https://doi.org/10.1093/qjmed/hcae175.042
Published:
20 November 2024

Abstract

Background

Measurement of intracranial pressure (ICP) is crucial in the management of many neurological conditions. However, due to the invasiveness, high cost, and required expertise of available ICP monitoring techniques, many patients who could benefit from ICP monitoring do not receive it. As a result, there has been a substantial effort to explore and develop novel non-invasive ICP monitoring techniques to improve the overall clinical care of patients who may be suffering from ICP disorders.

Objective

Assessment of the role of ultrasound as a non-invasive method (bedside) to measure the raising of intracranial pressure by measuring the optic nerve sheath diameter in traumatic and nontraumatic neurocritical patients.

Patients

and Methods: A total of 100 patients of both sexes above 18 years old diagnosed with traumatic & non-traumatic brain injury with high intracranial pressure (ICP) which suspected by the initial CT brain and Marshall Classification were enrolled. Patients were divided into control group that included 50 patients with no evidence of any intracranial abnormality or severe head injury. Mean ONSD in the control group was considered to be normal. Study group subjects included 50 patients aged above 18 years old who sustained a severe traumatic or non-traumatic brain injury (GCS <8) All patients had a non-contrast CT head b efore any surgical or non-surgical i ntervention. The CT head was used to determine the Marshall score.

Results

Optic nerve sheath diameter was statistically significant higher in all periods 0-24 hours among cases with high intracranial tension compared with control ones with statistically significant positive correlations between it and age at 6hrs. and 24hrs and Marshal score at Ohr. and 24hrs and negative correlation between it and GCS score at Ohr. and 24hrs. The best cut off value for detector of raised intracranial pressure was 4.9 with sensitivity 94.7%, specificity 83.3%, positive predictive value 94.7% and negative predictive value 83.3%.

Conclusion

The evaluation of the optic nerve sheath diameter is a simple non-invasive procedure, which is a potentially useful tool in the assessment and monitoring of traumatic and nontraumatic neurocritical patients suspected of having raised intracranial pressure.

This content is only available as a PDF.
This article is published and distributed under the terms of the Oxford University Press, Standard Journals Publication Model (https://dbpia.nl.go.kr/pages/standard-publication-reuse-rights)
Close
This Feature Is Available To Subscribers Only

Sign In or Create an Account

Close

This PDF is available to Subscribers Only

View Article Abstract & Purchase Options

For full access to this pdf, sign in to an existing account, or purchase an annual subscription.

Close

Gift article access

As a benefit of your subscription, you can share temporary access to restricted articles.

Each link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Please sign in to your personal account to gift article access.

Gift article access

Please create a link below to share with others. This will provide temporary access to this restricted article.

The link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Gift articles remaining: --

Gift article access

The link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Gift articles remaining: --

Gift article access

As a benefit of your subscription, you can share temporary access to restricted articles.

Each link will stop working after 30 days or 10 uses.

You have reached the limit of 10 links within a 30 day period