-
PDF
- Split View
-
Views
-
Cite
Cite
Michal Miroslaw Farkowski, Michal Karlinski, Sergio Barra, Rui Providencia, Dominik Golicki, Mariusz Pytkowski, Ante Anic, Julian Kyoung Ryul Chun, Carlo de Asmundis, Deirdre Anne Lane, Serge Boveda, Effectiveness and safety of a single freeze strategy of cryoballoon ablation of atrial fibrillation: an EHRA systematic review and meta-analysis, EP Europace, Volume 24, Issue 1, January 2022, Pages 58–69, https://doi.org/10.1093/europace/euab133
- Share Icon Share
Abstract
To conduct a systematic review and meta-analysis to compare the effectiveness and safety of cryoballoon ablation of atrial fibrillation (AF) performed using a single freeze strategy in comparison to an empiric double (‘bonus’) freeze strategy. We systematically searched MEDLINE, EMBASE, and CENTRAL databases from inception to 12 July 2020, for prospective and retrospective studies of patients undergoing cryoballoon for paroxysmal or persistent AF comparing a single vs. bonus freeze strategy. The main outcome was atrial arrhythmia-free survival and eligible studies required at least 12 months of follow-up; the primary safety outcome was a composite of all complications. Study quality was assessed using the Cochrane risk of bias tool and the Newcastle–Ottawa Scale. Thirteen studies (3 randomized controlled trials and 10 observational studies) comprising 3163 patients were eligible for inclusion (64% males, 71.5% paroxysmal AF, mean CHA2DS2-VASc score 1.3 ± 0.9). There was no significant difference in pooled effectiveness between single freeze strategy compared to double freeze strategy [relative risk (RR) 1.03; 95% confidence interval (CI): 0.98–1.07; I2 = 0%]. Single freeze procedures were associated with a significantly lower adverse event rate (RR 0.72; 95% CI: 0.53–0.98; I2 = 0%) and shorter average procedure time (90 ± 27 min vs. 121 ± 36 min, P < 0.001). A trend for lower risk of persistent phrenic nerve palsy was observed (RR 0.61; 95% CI: 0.37–1.01; I2 = 0%). The quality of included studies was moderate/good, with no evidence of significant publication bias. Single freeze strategy for cryoballoon of AF is as effective as an empiric double (‘bonus’) freeze strategy while appearing safer and probably quicker (PROSPERO registration number CRD42020158696).
This systematic review identified 13 studies comparing single freeze to double (‘bonus’) freeze cryoballoon strategy, including three randomized controlled trials.
During a ≥12-month follow-up, the single freeze strategy of cryoballoon ablation of atrial fibrillation (AF) was as effective as the double freeze strategy.
The single freeze strategy was associated with a lower risk of any adverse events and a strong trend for lower risk of persistent phrenic nerve palsy.
The single freeze strategy probably allows to shorten procedure duration.
These findings question the need for routine bonus freeze during cryoballoon ablation of AF.
Introduction
Catheter ablation is the most effective rhythm control strategy for atrial fibrillation (AF) patients, with the potential to improve prognosis in selected populations.1–3 Electrical isolation of the pulmonary veins is considered a crucial endpoint of AF ablation and can be achieved by a variety of ablation techniques, with radiofrequency ablation (RFA) and cryoballoon ablation being the most widely used.1,4 A large body of evidence indicates clinical equivalence of both ablation techniques in terms of arrhythmia recurrence, albeit with significant differences in procedure duration or safety.1,4–6 In two pivotal trials which compared cryoballoon ablation to RFA, all pulmonary veins were subject to at least two cryoballoon applications (double or ‘bonus’ freeze strategy) with a fixed time of freezing.7,8 The cryoballoon ablation technique has evolved with time, leading to a reduction in both the number and duration of applications.9–11 Recent studies report that even a single 180 s application with or without time-to-isolation (TTI) guidance (single freeze strategy) may be sufficient for a favourable long-term effect.10,12 Based on the published data, it is unclear how this evolution may influence the effectiveness and safety of cryoballoon ablation, especially considering that two recent multicentre trials investigating cryoballoon ablation effectiveness as a first-line treatment of AF used a ‘bonus’ freeze strategy.13–15
Therefore, we conducted a systematic review and meta-analysis of randomized and observational studies with a control group to evaluate the effectiveness and safety of a single freeze cryoballoon ablation of AF in comparison to the double (‘bonus’) freeze strategy.
Methods
This systematic review followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines.16 The protocol is registered in the international prospective register of systematic reviews (CRD42020158696).
Search strategy and selection criteria
MEDLINE (Medical Literature Analysis and Retrieval System Online) via PubMED, EMBASE (Excerpta Medical Database), and CENTRAL (Cochrane Central Register of Controlled Trials) databases were searched from inception to the 25 July 2019 using the following search string (cryo* AND ablation AND ‘atrial fibrillation’). Due to delay in completion of the review, the MEDLINE search was updated on 12 July 2020. Reference lists of eligible studies were searched for additional sources of information. Full-text publications of conference abstracts or registered clinical trials were sought. We also contacted key opinion leaders in the field of cryoballoon ablation to guarantee the inclusion of all relevant studies.
We included all prospective and retrospective studies with a control group which assessed the first-time cryoballoon ablation performed in adult patients with either paroxysmal or persistent AF using second or newest generation cryoballoons. Generations 2 to 4 are currently commercially available and do not differ significantly in terms of clinical performance. Only studies published in English were included.
The intervention assessed was cryoballoon ablation of AF. The comparison of interest was intended single freeze cryoballoon procedure (‘single freeze group’) vs. intended two cryoballoon applications or an empirical ‘bonus’ application after demonstrating pulmonary vein isolation (‘double/bonus freeze group’) regardless of the method used for assessment of pulmonary vein isolation (spiral catheter, TTI, etc.) or length of application. An additional freeze was allowed in the ‘single freeze group’ when it was felt that isolation was either not achieved or was achieved very late in the freeze, causing concerns for lesion durability.
Two investigators (M.M.F. and M.K.) independently screened and selected potentially eligible studies based on title and abstract. Final eligibility was decided after evaluation of full-text publications. All disagreements were resolved via discussion or through the involvement of a third referee (D.G.).
Data extraction and quality assessment
Data extraction was done independently by two investigators (M.M.F. and M.K.) and all disagreements were resolved via discussion, or through the involvement of a third referee (D.G.). A standardized form was used to extract the following information from each study: (i) study design and methodology, (ii) details of the ablation procedure (single or double application, TTI), (iii) information on the assessment of the main clinical outcome (surface ECG, Holter monitoring), including length of follow-up, (iv) baseline characteristics of participants (age, CHA2DS2-VASc score, paroxysmal and persistent AF, left atrial diameter), and (v) measures of effect and safety as stated in the protocol of the current meta-analysis. In case of missing data on main outcomes, authors of the original publications were contacted via email.
The risk of bias in randomized controlled trials (RCTs) was assessed using the Cochrane risk of bias tool,17 while the Newcastle–Ottawa Scale (NOS) was used to assess the quality of non-randomized studies. Critical assessments on the risk of bias (high, low, unclear) were done separately for each domain. The risk of bias assessment was done independently by two investigators (M.M.F. and M.K.) and all disagreements were resolved via discussion, or through the involvement of a third referee (D.G.). A trial was considered of high quality if no domains scored as high risk, or low quality if three or more domains scored as high risk. High-quality non-randomized studies were defined as those with a Newcastle–Ottawa score of ≥7.
Outcome measures
The main clinical outcome was atrial arrhythmia-free survival assessed at least 12 months from the date of the ablation, defined as the lack of any atrial arrhythmia (AF or other) lasting more than 30 s as assessed by repeated ECG and/or Holter monitoring. The main safety outcome was any adverse effects of the ablation. Secondary outcome measures included: persistent phrenic nerve palsy (PNP), defined as palsy lasting longer than until the end of the index ablation, transient PNP, defined as palsy which resolved before the end of the index ablation, tamponade, atrio-oesophageal fistula formation, procedure duration, and fluoroscopy time.
Data synthesis and analysis
Data were synthesized if reported in at least two included studies. Continuous variables were presented as mean with standard deviation (SD). If means and SD were not reported, these were estimated from sample size, medians and quartiles.18,19
We used random effect models to calculate pooled: (i) relative risk (RR) for freedom from any atrial arrhythmia in a ≥12-month follow-up, (ii) RR of ablation-associated persistent PNP, (iii) RR of ablation-associated transient PNP, (iv) RR of any ablation-associated adverse event, (v) difference in procedure duration time, and (vi) difference in fluoroscopy time, all with 95% confidence intervals (95% CIs).
Analyses were conducted separately for randomized and non-randomized studies. Subgroups were compared using the Z statistics. Heterogeneity between study populations was calculated using I2 statistics, where values of less than 25%, 50%, and 75% were regarded as evidence of low, moderate, and high levels of heterogeneity, respectively.20 Funnel plots were used for evaluating the presence of publication bias.
Analyses were performed using Statistica 13.3 (TIBCO Software Inc., CA, USA).
Results
Selection and description of studies
The PRISMA flow diagram in Figure 1 summarizes the study selection process. Primary searches identified 3930 citations and, after removal of duplicates, 2666 abstracts were independently screened by two investigators. Taking also into account additional searches (MEDLINE update, reference lists), a total of 16 potentially relevant studies were selected for full-text examination. Three studies were excluded based on the wrong comparator (no single freeze group in all cases13,29,30) and, finally, 13 studies were included in the data synthesis: 3 RCTs11,12,21 and 10 non-RCTs.9,10,12,22–28

PRISMA flow diagram for study selection process. a Update of the MEDLINE search, manual search of reference lists of included studies, contact with key opinion leaders. RCT, randomized controlled trial.
Characteristics of included studies
The characteristics of included studies comprising methodology, demographic data, cryoballoon ablation details, and follow-up strategies are provided in Tables 1 and 2. Five studies11,21,22,25,31 used a single freeze strategy based on the TTI principle, whereas investigators of two studies10,26 changed the ablation technique from empirical to TTI-guided applications over the course of their studies and six others used empirical 180/240 s applications.9,12,23,24,27,28 In all cases, pulmonary vein isolation was confirmed before the bonus freeze application. The diaphragmatic compound motor action potential assessment, an additional precaution measure for preventing PNP, was used in five studies.12,22,24–26 The definition of primary efficacy and safety endpoints were homogenous among included studies. Apart from two studies,21,31 effectiveness was defined as freedom from any atrial arrhythmia lasting >30 s recorded after a 3-month blanking period. Effectiveness was assessed during clinical visits and through repeated elective electrocardiograms (ECG) or Holter ECG monitoring of varying duration. In all studies, persistent PNP was defined as PNP lasting longer than completion of the index procedure.
First author, year, reference . | Study design (number of centres) . | Sample size . | Description of the procedure . | Demographic data . | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Study group . | Control group . | Study group . | Control group . | TTI . | CMAP . | Patients’ mean age . | Male sex (%) . | Paroxysmal AF (%) . | |||||
Study group . | Control group . | Study group . | Control group . | Study group . | Control group . | ||||||||
Heeger 2016 | Prospective cohort study (1) | 60 | 60 | Single 240 s application | 1 bonus 240 s application after PVI | 0 | 1 | 61 ± 11 | 62 ± 11 | 63 | 60 | 83 | 75 |
Tebbenjohanns 2016 | Prospective cohort study with a historical control group (2) | 53 | 139 | Single 240 s application, adenosine challenge | Two 240 s applications | 0 | 0 | 66 ± 10 | 61 ± 11 | 51 | 54 | 72 | 63 |
Chun 2017 | Randomized controlled trial (1) | 50 | 50 | TTI <75 s or within 25 s after a pull-down, application 240 s; TTI >75 s or not recorded, application 240 s and 240 s bonus | Two 240 s applications | 1 | 0 | 66 ± 10 | 63 ± 12 | 60 | 58 | 100 | 100 |
Ekizler 2017 | Prospective cohort study (1) | 56 | 80 | Single application 240 s | 1 bonus application after PVI | 0 | 0 | 58 (48–67) | 62 (49–68) | 57 | 55 | 100 | 100 |
Aryana 2017 | Prospective cohort study (5) | 355 | 400 | TTI ≤60 s, one application TTI + 120 s; TTI 60–90 s, one application TTI + 120s and bonus 120 s; TTI >90 s, application aborted; no TT-PVI, 180 s application plus 120 s bonus | 2–3 applications lasting 2–4 min | 1 | 1 | 64 ± 11 | 63 ± 11 | 69 | 74 | 72 | 74 |
Ströker 2018 | Case-control study with propensity scoring (2) | 256 | 256 | Single 180/240 min application; bonus application if: temperature >−40°C within 1 min, no PVI or early spontaneous PV reconnection | 1–2 bonus application(s) (240 s/180s) after PVI | 0 | 0 | 59 ± 12 | 60 ± 11 | 62 | 67 | 82 | 79 |
Pott 2018 | Case-control study (1) | 100 | 100 | TTI <30 s, application 120 s; TTI 30–60 s, single application 180 s; TTI >60 s, 180 s application + 180 s bonus; no TTI recording, single 180 s application | Two 240 s applications | 1 | 1 | 65 ± 10.9 | 65.3 ± 11.3 | 56 | 57 | 65 | 69 |
Rottner 2018a | Prospective cohort study (2) | 352 | 211 | Single 240 s application; later single application TTI + 120 s and if no TTI recording, single 180 s application | Two 240 s applications | 1 | 1 | 63.3 ± 10.9 | 63.3 ± 10.9 | 64 | 64 | 58 | 58 |
Mortsell 2018 | Randomized controlled trial (1) | 69 | 70 | Single 240 s application; either TTI or temp. ≤40°C within 120 s | Two 240 s applications | 1 | 0 | 61.9 ± 9.08 | 68.3 ± 10.0 | 70 | 77 | 49.3 | 40.0 |
Yoshiga 2019 | Prospective cohort study (1) | 67 | 33 | Single application ≥180 min | 1 bonus 120 s application after PVI | 0 | 0 | 65.1 ± 10.0 | 67.5 ± 8.3 | 58 | 70 | 100 | 100 |
Cordes 2019 | Prospective cohort study (1) | 35 | 35 | TTI + 120 s; if TTI not recorded, single 180 s application with target temp. <40°C; if TTI >90 s, application aborted | Two 180 s applications | 1 | 0 | 58 (IQR 16) | 60 (IQR 20) | 71 | 80 | 60 | 57 |
Miyamoto 2019 | Randomized controlled trial (3) | 55 | 55 | Single 180 s application | 1 bonus 180 s application after PVI | 0 | 1 | 63.1 ± 11.8 | 64.0 ± 11.0 | 65.5 | 63.6 | 100 | 100 |
Koektuerk 2019 | Case-control study (1) | 77 | 92 | Single 240 s application | Two 240 s applications | 0 | 0 | 61 ± 10 | 64 ± 10 | 63.6 | 85.9 | 100 | 100 |
First author, year, reference . | Study design (number of centres) . | Sample size . | Description of the procedure . | Demographic data . | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Study group . | Control group . | Study group . | Control group . | TTI . | CMAP . | Patients’ mean age . | Male sex (%) . | Paroxysmal AF (%) . | |||||
Study group . | Control group . | Study group . | Control group . | Study group . | Control group . | ||||||||
Heeger 2016 | Prospective cohort study (1) | 60 | 60 | Single 240 s application | 1 bonus 240 s application after PVI | 0 | 1 | 61 ± 11 | 62 ± 11 | 63 | 60 | 83 | 75 |
Tebbenjohanns 2016 | Prospective cohort study with a historical control group (2) | 53 | 139 | Single 240 s application, adenosine challenge | Two 240 s applications | 0 | 0 | 66 ± 10 | 61 ± 11 | 51 | 54 | 72 | 63 |
Chun 2017 | Randomized controlled trial (1) | 50 | 50 | TTI <75 s or within 25 s after a pull-down, application 240 s; TTI >75 s or not recorded, application 240 s and 240 s bonus | Two 240 s applications | 1 | 0 | 66 ± 10 | 63 ± 12 | 60 | 58 | 100 | 100 |
Ekizler 2017 | Prospective cohort study (1) | 56 | 80 | Single application 240 s | 1 bonus application after PVI | 0 | 0 | 58 (48–67) | 62 (49–68) | 57 | 55 | 100 | 100 |
Aryana 2017 | Prospective cohort study (5) | 355 | 400 | TTI ≤60 s, one application TTI + 120 s; TTI 60–90 s, one application TTI + 120s and bonus 120 s; TTI >90 s, application aborted; no TT-PVI, 180 s application plus 120 s bonus | 2–3 applications lasting 2–4 min | 1 | 1 | 64 ± 11 | 63 ± 11 | 69 | 74 | 72 | 74 |
Ströker 2018 | Case-control study with propensity scoring (2) | 256 | 256 | Single 180/240 min application; bonus application if: temperature >−40°C within 1 min, no PVI or early spontaneous PV reconnection | 1–2 bonus application(s) (240 s/180s) after PVI | 0 | 0 | 59 ± 12 | 60 ± 11 | 62 | 67 | 82 | 79 |
Pott 2018 | Case-control study (1) | 100 | 100 | TTI <30 s, application 120 s; TTI 30–60 s, single application 180 s; TTI >60 s, 180 s application + 180 s bonus; no TTI recording, single 180 s application | Two 240 s applications | 1 | 1 | 65 ± 10.9 | 65.3 ± 11.3 | 56 | 57 | 65 | 69 |
Rottner 2018a | Prospective cohort study (2) | 352 | 211 | Single 240 s application; later single application TTI + 120 s and if no TTI recording, single 180 s application | Two 240 s applications | 1 | 1 | 63.3 ± 10.9 | 63.3 ± 10.9 | 64 | 64 | 58 | 58 |
Mortsell 2018 | Randomized controlled trial (1) | 69 | 70 | Single 240 s application; either TTI or temp. ≤40°C within 120 s | Two 240 s applications | 1 | 0 | 61.9 ± 9.08 | 68.3 ± 10.0 | 70 | 77 | 49.3 | 40.0 |
Yoshiga 2019 | Prospective cohort study (1) | 67 | 33 | Single application ≥180 min | 1 bonus 120 s application after PVI | 0 | 0 | 65.1 ± 10.0 | 67.5 ± 8.3 | 58 | 70 | 100 | 100 |
Cordes 2019 | Prospective cohort study (1) | 35 | 35 | TTI + 120 s; if TTI not recorded, single 180 s application with target temp. <40°C; if TTI >90 s, application aborted | Two 180 s applications | 1 | 0 | 58 (IQR 16) | 60 (IQR 20) | 71 | 80 | 60 | 57 |
Miyamoto 2019 | Randomized controlled trial (3) | 55 | 55 | Single 180 s application | 1 bonus 180 s application after PVI | 0 | 1 | 63.1 ± 11.8 | 64.0 ± 11.0 | 65.5 | 63.6 | 100 | 100 |
Koektuerk 2019 | Case-control study (1) | 77 | 92 | Single 240 s application | Two 240 s applications | 0 | 0 | 61 ± 10 | 64 ± 10 | 63.6 | 85.9 | 100 | 100 |
AF, atrial fibrillation; AT, atrial tachycardia; CMAP, compound motor action potentials; IQR, interquartile range; PVI, pulmonary vein isolation, TTI, time to isolation.
Rottner 2018 reported aggregated demographic data for all patient groups.
First author, year, reference . | Study design (number of centres) . | Sample size . | Description of the procedure . | Demographic data . | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Study group . | Control group . | Study group . | Control group . | TTI . | CMAP . | Patients’ mean age . | Male sex (%) . | Paroxysmal AF (%) . | |||||
Study group . | Control group . | Study group . | Control group . | Study group . | Control group . | ||||||||
Heeger 2016 | Prospective cohort study (1) | 60 | 60 | Single 240 s application | 1 bonus 240 s application after PVI | 0 | 1 | 61 ± 11 | 62 ± 11 | 63 | 60 | 83 | 75 |
Tebbenjohanns 2016 | Prospective cohort study with a historical control group (2) | 53 | 139 | Single 240 s application, adenosine challenge | Two 240 s applications | 0 | 0 | 66 ± 10 | 61 ± 11 | 51 | 54 | 72 | 63 |
Chun 2017 | Randomized controlled trial (1) | 50 | 50 | TTI <75 s or within 25 s after a pull-down, application 240 s; TTI >75 s or not recorded, application 240 s and 240 s bonus | Two 240 s applications | 1 | 0 | 66 ± 10 | 63 ± 12 | 60 | 58 | 100 | 100 |
Ekizler 2017 | Prospective cohort study (1) | 56 | 80 | Single application 240 s | 1 bonus application after PVI | 0 | 0 | 58 (48–67) | 62 (49–68) | 57 | 55 | 100 | 100 |
Aryana 2017 | Prospective cohort study (5) | 355 | 400 | TTI ≤60 s, one application TTI + 120 s; TTI 60–90 s, one application TTI + 120s and bonus 120 s; TTI >90 s, application aborted; no TT-PVI, 180 s application plus 120 s bonus | 2–3 applications lasting 2–4 min | 1 | 1 | 64 ± 11 | 63 ± 11 | 69 | 74 | 72 | 74 |
Ströker 2018 | Case-control study with propensity scoring (2) | 256 | 256 | Single 180/240 min application; bonus application if: temperature >−40°C within 1 min, no PVI or early spontaneous PV reconnection | 1–2 bonus application(s) (240 s/180s) after PVI | 0 | 0 | 59 ± 12 | 60 ± 11 | 62 | 67 | 82 | 79 |
Pott 2018 | Case-control study (1) | 100 | 100 | TTI <30 s, application 120 s; TTI 30–60 s, single application 180 s; TTI >60 s, 180 s application + 180 s bonus; no TTI recording, single 180 s application | Two 240 s applications | 1 | 1 | 65 ± 10.9 | 65.3 ± 11.3 | 56 | 57 | 65 | 69 |
Rottner 2018a | Prospective cohort study (2) | 352 | 211 | Single 240 s application; later single application TTI + 120 s and if no TTI recording, single 180 s application | Two 240 s applications | 1 | 1 | 63.3 ± 10.9 | 63.3 ± 10.9 | 64 | 64 | 58 | 58 |
Mortsell 2018 | Randomized controlled trial (1) | 69 | 70 | Single 240 s application; either TTI or temp. ≤40°C within 120 s | Two 240 s applications | 1 | 0 | 61.9 ± 9.08 | 68.3 ± 10.0 | 70 | 77 | 49.3 | 40.0 |
Yoshiga 2019 | Prospective cohort study (1) | 67 | 33 | Single application ≥180 min | 1 bonus 120 s application after PVI | 0 | 0 | 65.1 ± 10.0 | 67.5 ± 8.3 | 58 | 70 | 100 | 100 |
Cordes 2019 | Prospective cohort study (1) | 35 | 35 | TTI + 120 s; if TTI not recorded, single 180 s application with target temp. <40°C; if TTI >90 s, application aborted | Two 180 s applications | 1 | 0 | 58 (IQR 16) | 60 (IQR 20) | 71 | 80 | 60 | 57 |
Miyamoto 2019 | Randomized controlled trial (3) | 55 | 55 | Single 180 s application | 1 bonus 180 s application after PVI | 0 | 1 | 63.1 ± 11.8 | 64.0 ± 11.0 | 65.5 | 63.6 | 100 | 100 |
Koektuerk 2019 | Case-control study (1) | 77 | 92 | Single 240 s application | Two 240 s applications | 0 | 0 | 61 ± 10 | 64 ± 10 | 63.6 | 85.9 | 100 | 100 |
First author, year, reference . | Study design (number of centres) . | Sample size . | Description of the procedure . | Demographic data . | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Study group . | Control group . | Study group . | Control group . | TTI . | CMAP . | Patients’ mean age . | Male sex (%) . | Paroxysmal AF (%) . | |||||
Study group . | Control group . | Study group . | Control group . | Study group . | Control group . | ||||||||
Heeger 2016 | Prospective cohort study (1) | 60 | 60 | Single 240 s application | 1 bonus 240 s application after PVI | 0 | 1 | 61 ± 11 | 62 ± 11 | 63 | 60 | 83 | 75 |
Tebbenjohanns 2016 | Prospective cohort study with a historical control group (2) | 53 | 139 | Single 240 s application, adenosine challenge | Two 240 s applications | 0 | 0 | 66 ± 10 | 61 ± 11 | 51 | 54 | 72 | 63 |
Chun 2017 | Randomized controlled trial (1) | 50 | 50 | TTI <75 s or within 25 s after a pull-down, application 240 s; TTI >75 s or not recorded, application 240 s and 240 s bonus | Two 240 s applications | 1 | 0 | 66 ± 10 | 63 ± 12 | 60 | 58 | 100 | 100 |
Ekizler 2017 | Prospective cohort study (1) | 56 | 80 | Single application 240 s | 1 bonus application after PVI | 0 | 0 | 58 (48–67) | 62 (49–68) | 57 | 55 | 100 | 100 |
Aryana 2017 | Prospective cohort study (5) | 355 | 400 | TTI ≤60 s, one application TTI + 120 s; TTI 60–90 s, one application TTI + 120s and bonus 120 s; TTI >90 s, application aborted; no TT-PVI, 180 s application plus 120 s bonus | 2–3 applications lasting 2–4 min | 1 | 1 | 64 ± 11 | 63 ± 11 | 69 | 74 | 72 | 74 |
Ströker 2018 | Case-control study with propensity scoring (2) | 256 | 256 | Single 180/240 min application; bonus application if: temperature >−40°C within 1 min, no PVI or early spontaneous PV reconnection | 1–2 bonus application(s) (240 s/180s) after PVI | 0 | 0 | 59 ± 12 | 60 ± 11 | 62 | 67 | 82 | 79 |
Pott 2018 | Case-control study (1) | 100 | 100 | TTI <30 s, application 120 s; TTI 30–60 s, single application 180 s; TTI >60 s, 180 s application + 180 s bonus; no TTI recording, single 180 s application | Two 240 s applications | 1 | 1 | 65 ± 10.9 | 65.3 ± 11.3 | 56 | 57 | 65 | 69 |
Rottner 2018a | Prospective cohort study (2) | 352 | 211 | Single 240 s application; later single application TTI + 120 s and if no TTI recording, single 180 s application | Two 240 s applications | 1 | 1 | 63.3 ± 10.9 | 63.3 ± 10.9 | 64 | 64 | 58 | 58 |
Mortsell 2018 | Randomized controlled trial (1) | 69 | 70 | Single 240 s application; either TTI or temp. ≤40°C within 120 s | Two 240 s applications | 1 | 0 | 61.9 ± 9.08 | 68.3 ± 10.0 | 70 | 77 | 49.3 | 40.0 |
Yoshiga 2019 | Prospective cohort study (1) | 67 | 33 | Single application ≥180 min | 1 bonus 120 s application after PVI | 0 | 0 | 65.1 ± 10.0 | 67.5 ± 8.3 | 58 | 70 | 100 | 100 |
Cordes 2019 | Prospective cohort study (1) | 35 | 35 | TTI + 120 s; if TTI not recorded, single 180 s application with target temp. <40°C; if TTI >90 s, application aborted | Two 180 s applications | 1 | 0 | 58 (IQR 16) | 60 (IQR 20) | 71 | 80 | 60 | 57 |
Miyamoto 2019 | Randomized controlled trial (3) | 55 | 55 | Single 180 s application | 1 bonus 180 s application after PVI | 0 | 1 | 63.1 ± 11.8 | 64.0 ± 11.0 | 65.5 | 63.6 | 100 | 100 |
Koektuerk 2019 | Case-control study (1) | 77 | 92 | Single 240 s application | Two 240 s applications | 0 | 0 | 61 ± 10 | 64 ± 10 | 63.6 | 85.9 | 100 | 100 |
AF, atrial fibrillation; AT, atrial tachycardia; CMAP, compound motor action potentials; IQR, interquartile range; PVI, pulmonary vein isolation, TTI, time to isolation.
Rottner 2018 reported aggregated demographic data for all patient groups.
First author, year, reference . | Assessment of the primary end point . | Standard AF ablation endpointa . | Mean follow-up time . | AADs management . | Information on redo procedures . | ||
---|---|---|---|---|---|---|---|
Study group . | Control group . | All patients . | |||||
Heeger 2016 | ECG and 24 h Holter at 3, 6, 12 months and in 6-month intervals thereafter; regular telephonic interviews, additional outpatient visits in symptomatic patients | 1 | 848 ± 101 days | 849 ± 74 days | AADs continued for 3 months | A total of 26/34 (76 %) patients suffering from atrial arrhythmia recurrences underwent a second ablation | |
Tebbenjohanns 2016 | Clinical visit and 24 h Holter at 3, 6, 12, and 18 months; external event recording for 4 weeks in symptomatic patients | 1 | 458 ± 107 days | Not reported | Not reported | ||
Chun 2017 | Visits at 3, 6, 12 months; ECG and 72-h Holter ECG; additional telephone interviews and event recording in symptomatic patients | 1 | 372 (351–455) days | 378(361–483) days | AADs discontinued after the procedure. Resumption of AADs in case of AF relapse during blanking period | Not reported | |
Ekizler 2017 | ECG and 24 h Holter at 1, 3, 6 and 12 month, biannually thereafter | 1 | 12 ± 3 months after blanking period | 13 ± 3 months after blanking period | Discontinued at the end of the blanking period | A redo procedure was performed in five patients in Study group and in six patients in Control group | |
Aryana 2017 | ECG during each follow-up visit; 2- to 4-week ambulatory electrocardiographic monitoring at 6 weeks, 3 and 6 months | 1 | 15 ± 2 month | 16 ± 3 month | Antiarrhythmic therapy was discontinued within 6 weeks of ablation | 35 patients (9.9%) in Study group and 63 patients (15.7%) in Control group underwent a repeat catheter ablation during the study period | |
Ströker 2018 | ECG, Holter at 1, 3, 6 month and every 6 month after or in case of symptoms | 1 | 18 ± 10 months | AAD’s were discontinued 3 months post-ablation if no recurrence | A redo procedure was performed in 44 (66%) patients in the Control group and 37 (50%) patients in the Study group | ||
Pott 2018 | Clinical assessment, echocardiography, ECG, and 7-day-Holter-monitoring at 1, 3, and 6 months and thereafter every 6 months | 1 | 436 ± 184 days | AADs withheld either after the procedure or after blanking period | Not reported | ||
Rottner 2018 | No information provided; paper focused on procedure safety | NA | NA | NA | NA | AADs recommended to be continued for 3 months | NA |
Mortsell 2018 | Clinical visit at 3, 6, and 12 months; a 7 day Holter at 6 and 12 months | 1 (1 month blanking period) | 12 months | 12 months | Antiarrhythmic drugs were withdrawn after 3 months in asymptomatic patients free from clinical AF recurrences | Re-ablations were performed in 7 of 70 (10%) patients in the Study group and in 8 of 70 (11.4%) patients in the Control group | |
Yoshiga 2019 | ECG and Holter at 1, 3, 6, and 12 months; event monitoring in symptomatic patients | 1 | 12 months | 12 months | In all the patients the anti-arrhythmic drugs were discontinued after the procedure | Not reported | |
Cordes 219 | Standardized telephone interview at 3 and 6 months | b | 6 months | 6 months | Not reported | Not reported | |
Miyamoto 2019 | ECG at 1 month, and then every 1–3 months; 24 h Holter at 3 and 12 month; event recorder in symptomatic patients | 1 | 12 months | 12 months | Discontinuation of antiarrhythmic drugs was recommended after the ablation | Not reported | |
Koektuerk 2019 | Outpatient visit at 1, 3, 6, 12 months or earlier if symptomatic; 7-day Holter recording at 3 and 6 months and 24-h Holter later; telephone interview at the end of the follow-up | 1 | 16.4 ± 7.5 | 19.0 ± 8.6 | AADs continued for at least 3 months after ablation | 7 patients in the Study group and 14 in the Control group underwent repeated ablation |
First author, year, reference . | Assessment of the primary end point . | Standard AF ablation endpointa . | Mean follow-up time . | AADs management . | Information on redo procedures . | ||
---|---|---|---|---|---|---|---|
Study group . | Control group . | All patients . | |||||
Heeger 2016 | ECG and 24 h Holter at 3, 6, 12 months and in 6-month intervals thereafter; regular telephonic interviews, additional outpatient visits in symptomatic patients | 1 | 848 ± 101 days | 849 ± 74 days | AADs continued for 3 months | A total of 26/34 (76 %) patients suffering from atrial arrhythmia recurrences underwent a second ablation | |
Tebbenjohanns 2016 | Clinical visit and 24 h Holter at 3, 6, 12, and 18 months; external event recording for 4 weeks in symptomatic patients | 1 | 458 ± 107 days | Not reported | Not reported | ||
Chun 2017 | Visits at 3, 6, 12 months; ECG and 72-h Holter ECG; additional telephone interviews and event recording in symptomatic patients | 1 | 372 (351–455) days | 378(361–483) days | AADs discontinued after the procedure. Resumption of AADs in case of AF relapse during blanking period | Not reported | |
Ekizler 2017 | ECG and 24 h Holter at 1, 3, 6 and 12 month, biannually thereafter | 1 | 12 ± 3 months after blanking period | 13 ± 3 months after blanking period | Discontinued at the end of the blanking period | A redo procedure was performed in five patients in Study group and in six patients in Control group | |
Aryana 2017 | ECG during each follow-up visit; 2- to 4-week ambulatory electrocardiographic monitoring at 6 weeks, 3 and 6 months | 1 | 15 ± 2 month | 16 ± 3 month | Antiarrhythmic therapy was discontinued within 6 weeks of ablation | 35 patients (9.9%) in Study group and 63 patients (15.7%) in Control group underwent a repeat catheter ablation during the study period | |
Ströker 2018 | ECG, Holter at 1, 3, 6 month and every 6 month after or in case of symptoms | 1 | 18 ± 10 months | AAD’s were discontinued 3 months post-ablation if no recurrence | A redo procedure was performed in 44 (66%) patients in the Control group and 37 (50%) patients in the Study group | ||
Pott 2018 | Clinical assessment, echocardiography, ECG, and 7-day-Holter-monitoring at 1, 3, and 6 months and thereafter every 6 months | 1 | 436 ± 184 days | AADs withheld either after the procedure or after blanking period | Not reported | ||
Rottner 2018 | No information provided; paper focused on procedure safety | NA | NA | NA | NA | AADs recommended to be continued for 3 months | NA |
Mortsell 2018 | Clinical visit at 3, 6, and 12 months; a 7 day Holter at 6 and 12 months | 1 (1 month blanking period) | 12 months | 12 months | Antiarrhythmic drugs were withdrawn after 3 months in asymptomatic patients free from clinical AF recurrences | Re-ablations were performed in 7 of 70 (10%) patients in the Study group and in 8 of 70 (11.4%) patients in the Control group | |
Yoshiga 2019 | ECG and Holter at 1, 3, 6, and 12 months; event monitoring in symptomatic patients | 1 | 12 months | 12 months | In all the patients the anti-arrhythmic drugs were discontinued after the procedure | Not reported | |
Cordes 219 | Standardized telephone interview at 3 and 6 months | b | 6 months | 6 months | Not reported | Not reported | |
Miyamoto 2019 | ECG at 1 month, and then every 1–3 months; 24 h Holter at 3 and 12 month; event recorder in symptomatic patients | 1 | 12 months | 12 months | Discontinuation of antiarrhythmic drugs was recommended after the ablation | Not reported | |
Koektuerk 2019 | Outpatient visit at 1, 3, 6, 12 months or earlier if symptomatic; 7-day Holter recording at 3 and 6 months and 24-h Holter later; telephone interview at the end of the follow-up | 1 | 16.4 ± 7.5 | 19.0 ± 8.6 | AADs continued for at least 3 months after ablation | 7 patients in the Study group and 14 in the Control group underwent repeated ablation |
AADs, antiarrhythmic drugs; AF, atrial fibrillation; AT, atrial tachycardia.
Defined as AF/AT episode lasting more than 30 s recorded after a 3 month blanking period.
Only 6 month follow-up results available.
First author, year, reference . | Assessment of the primary end point . | Standard AF ablation endpointa . | Mean follow-up time . | AADs management . | Information on redo procedures . | ||
---|---|---|---|---|---|---|---|
Study group . | Control group . | All patients . | |||||
Heeger 2016 | ECG and 24 h Holter at 3, 6, 12 months and in 6-month intervals thereafter; regular telephonic interviews, additional outpatient visits in symptomatic patients | 1 | 848 ± 101 days | 849 ± 74 days | AADs continued for 3 months | A total of 26/34 (76 %) patients suffering from atrial arrhythmia recurrences underwent a second ablation | |
Tebbenjohanns 2016 | Clinical visit and 24 h Holter at 3, 6, 12, and 18 months; external event recording for 4 weeks in symptomatic patients | 1 | 458 ± 107 days | Not reported | Not reported | ||
Chun 2017 | Visits at 3, 6, 12 months; ECG and 72-h Holter ECG; additional telephone interviews and event recording in symptomatic patients | 1 | 372 (351–455) days | 378(361–483) days | AADs discontinued after the procedure. Resumption of AADs in case of AF relapse during blanking period | Not reported | |
Ekizler 2017 | ECG and 24 h Holter at 1, 3, 6 and 12 month, biannually thereafter | 1 | 12 ± 3 months after blanking period | 13 ± 3 months after blanking period | Discontinued at the end of the blanking period | A redo procedure was performed in five patients in Study group and in six patients in Control group | |
Aryana 2017 | ECG during each follow-up visit; 2- to 4-week ambulatory electrocardiographic monitoring at 6 weeks, 3 and 6 months | 1 | 15 ± 2 month | 16 ± 3 month | Antiarrhythmic therapy was discontinued within 6 weeks of ablation | 35 patients (9.9%) in Study group and 63 patients (15.7%) in Control group underwent a repeat catheter ablation during the study period | |
Ströker 2018 | ECG, Holter at 1, 3, 6 month and every 6 month after or in case of symptoms | 1 | 18 ± 10 months | AAD’s were discontinued 3 months post-ablation if no recurrence | A redo procedure was performed in 44 (66%) patients in the Control group and 37 (50%) patients in the Study group | ||
Pott 2018 | Clinical assessment, echocardiography, ECG, and 7-day-Holter-monitoring at 1, 3, and 6 months and thereafter every 6 months | 1 | 436 ± 184 days | AADs withheld either after the procedure or after blanking period | Not reported | ||
Rottner 2018 | No information provided; paper focused on procedure safety | NA | NA | NA | NA | AADs recommended to be continued for 3 months | NA |
Mortsell 2018 | Clinical visit at 3, 6, and 12 months; a 7 day Holter at 6 and 12 months | 1 (1 month blanking period) | 12 months | 12 months | Antiarrhythmic drugs were withdrawn after 3 months in asymptomatic patients free from clinical AF recurrences | Re-ablations were performed in 7 of 70 (10%) patients in the Study group and in 8 of 70 (11.4%) patients in the Control group | |
Yoshiga 2019 | ECG and Holter at 1, 3, 6, and 12 months; event monitoring in symptomatic patients | 1 | 12 months | 12 months | In all the patients the anti-arrhythmic drugs were discontinued after the procedure | Not reported | |
Cordes 219 | Standardized telephone interview at 3 and 6 months | b | 6 months | 6 months | Not reported | Not reported | |
Miyamoto 2019 | ECG at 1 month, and then every 1–3 months; 24 h Holter at 3 and 12 month; event recorder in symptomatic patients | 1 | 12 months | 12 months | Discontinuation of antiarrhythmic drugs was recommended after the ablation | Not reported | |
Koektuerk 2019 | Outpatient visit at 1, 3, 6, 12 months or earlier if symptomatic; 7-day Holter recording at 3 and 6 months and 24-h Holter later; telephone interview at the end of the follow-up | 1 | 16.4 ± 7.5 | 19.0 ± 8.6 | AADs continued for at least 3 months after ablation | 7 patients in the Study group and 14 in the Control group underwent repeated ablation |
First author, year, reference . | Assessment of the primary end point . | Standard AF ablation endpointa . | Mean follow-up time . | AADs management . | Information on redo procedures . | ||
---|---|---|---|---|---|---|---|
Study group . | Control group . | All patients . | |||||
Heeger 2016 | ECG and 24 h Holter at 3, 6, 12 months and in 6-month intervals thereafter; regular telephonic interviews, additional outpatient visits in symptomatic patients | 1 | 848 ± 101 days | 849 ± 74 days | AADs continued for 3 months | A total of 26/34 (76 %) patients suffering from atrial arrhythmia recurrences underwent a second ablation | |
Tebbenjohanns 2016 | Clinical visit and 24 h Holter at 3, 6, 12, and 18 months; external event recording for 4 weeks in symptomatic patients | 1 | 458 ± 107 days | Not reported | Not reported | ||
Chun 2017 | Visits at 3, 6, 12 months; ECG and 72-h Holter ECG; additional telephone interviews and event recording in symptomatic patients | 1 | 372 (351–455) days | 378(361–483) days | AADs discontinued after the procedure. Resumption of AADs in case of AF relapse during blanking period | Not reported | |
Ekizler 2017 | ECG and 24 h Holter at 1, 3, 6 and 12 month, biannually thereafter | 1 | 12 ± 3 months after blanking period | 13 ± 3 months after blanking period | Discontinued at the end of the blanking period | A redo procedure was performed in five patients in Study group and in six patients in Control group | |
Aryana 2017 | ECG during each follow-up visit; 2- to 4-week ambulatory electrocardiographic monitoring at 6 weeks, 3 and 6 months | 1 | 15 ± 2 month | 16 ± 3 month | Antiarrhythmic therapy was discontinued within 6 weeks of ablation | 35 patients (9.9%) in Study group and 63 patients (15.7%) in Control group underwent a repeat catheter ablation during the study period | |
Ströker 2018 | ECG, Holter at 1, 3, 6 month and every 6 month after or in case of symptoms | 1 | 18 ± 10 months | AAD’s were discontinued 3 months post-ablation if no recurrence | A redo procedure was performed in 44 (66%) patients in the Control group and 37 (50%) patients in the Study group | ||
Pott 2018 | Clinical assessment, echocardiography, ECG, and 7-day-Holter-monitoring at 1, 3, and 6 months and thereafter every 6 months | 1 | 436 ± 184 days | AADs withheld either after the procedure or after blanking period | Not reported | ||
Rottner 2018 | No information provided; paper focused on procedure safety | NA | NA | NA | NA | AADs recommended to be continued for 3 months | NA |
Mortsell 2018 | Clinical visit at 3, 6, and 12 months; a 7 day Holter at 6 and 12 months | 1 (1 month blanking period) | 12 months | 12 months | Antiarrhythmic drugs were withdrawn after 3 months in asymptomatic patients free from clinical AF recurrences | Re-ablations were performed in 7 of 70 (10%) patients in the Study group and in 8 of 70 (11.4%) patients in the Control group | |
Yoshiga 2019 | ECG and Holter at 1, 3, 6, and 12 months; event monitoring in symptomatic patients | 1 | 12 months | 12 months | In all the patients the anti-arrhythmic drugs were discontinued after the procedure | Not reported | |
Cordes 219 | Standardized telephone interview at 3 and 6 months | b | 6 months | 6 months | Not reported | Not reported | |
Miyamoto 2019 | ECG at 1 month, and then every 1–3 months; 24 h Holter at 3 and 12 month; event recorder in symptomatic patients | 1 | 12 months | 12 months | Discontinuation of antiarrhythmic drugs was recommended after the ablation | Not reported | |
Koektuerk 2019 | Outpatient visit at 1, 3, 6, 12 months or earlier if symptomatic; 7-day Holter recording at 3 and 6 months and 24-h Holter later; telephone interview at the end of the follow-up | 1 | 16.4 ± 7.5 | 19.0 ± 8.6 | AADs continued for at least 3 months after ablation | 7 patients in the Study group and 14 in the Control group underwent repeated ablation |
AADs, antiarrhythmic drugs; AF, atrial fibrillation; AT, atrial tachycardia.
Defined as AF/AT episode lasting more than 30 s recorded after a 3 month blanking period.
Only 6 month follow-up results available.
Risk of bias
The overall quality of the included studies was good or moderate (Supplementary material online, Tables S1 and S2). All three RCTs lacked blinding of participants and/or personnel to the intervention, but otherwise had no other major source of bias. All observational studies had a control group and derived data directly from medical records. The NOS score varied between 8 and 9 which was consistently above the established cut-off for high-quality observational studies; in one case26 there was not sufficient data to conduct a proper classification.
Data synthesis
The 13 included studies comprised 3163 patients, predominantly males (64%) with paroxysmal AF (71.5%) and at low risk of stroke (Table 3). The pooled data revealed that the cryoballoon ablation single freeze strategy was as effective as the double freeze strategy in preventing recurrent atrial arrhythmia [OR 1.09; 95% CI (0.90–1.32), P = 0.386; I2 = 0%, Figure 2A] while associating with a significantly lower risk of overall adverse events [RR 0.72; 95% CI (0.53–0.98); P = 0.037; I2 = 0%; Figure 2B] and borderline lower risk of persistent PNP [RR 0.61; 95% CI (0.37–1.01); P = 0.056; I2 = 0%; Figure 3A]. These results were similar when calculated for RCTs and non-RCTs separately (Figure 2A and B). Furthermore, the duration of single freeze procedures appeared shorter with notably high heterogeneity (90 ± 27 min. vs. 121 ± 36 min.; P < 0.001; I2 = 96%; Figure 3B). There was no difference between both strategies in terms of fluoroscopy times or risk of transient PNP (Supplementary material online, Figures S1 and S2). Funnel plots did not reveal any significant publication bias for the main efficacy and safety endpoints (Supplementary material online, Figure S3).

Forest plots of primary efficacy and safety outcomes. (A) Relative risk of freedom from any atrial arrhythmia in the 12-month follow-up. Test for subgroup differences: Z = 0.437 (P = 0.662). Overall heterogeneity: I2 = 0.00%. (B) Relative risk of any adverse event associated in randomized and non-randomized studies. Test for subgroup differences: Z = −1.183 (P = 0.238). Overall heterogeneity: I2 = 0.00%. 95% CI, 95% confidence interval; RCT, randomized clinical trial; RR, relative risk.

Forest plots of most important secondary outcomes. (A) Relative risk of ablation-associated persistent phrenic nerve palsy in randomized and non-randomized studies. Test for subgroup differences: Z = −0.627 (P = 0.531). Overall heterogeneity: I2 = 0.00%. (B) Difference between double freeze and single freeze procedure duration in randomized and non-randomized studies (presented in minutes). Test for subgroup differences: Z = 1.957 (P = 0.050). Overall heterogeneity: I2 = 95.72%. 95% CI, 95% confidence interval; RCT, randomized clinical trial; RR, relative risk.
. | Overall . | |||
---|---|---|---|---|
. | N . | Value . | ||
Age (years) | 3163 | 61.3 ± 10.8 | ||
Male sex | 3163 | 2025 (64.0) | ||
Paroxysmal AF | 3163 | 2261 (71.5) | ||
CHA2DS2-VASC score | 2069 | 1.3 ± 0.90 | ||
BMI (kg/m2) | 2339 | 28.0 ± 5.3 | ||
Left atrial diameter (mm) | 2818 | 42.7 ± 6.9 | ||
Single freeze | Repeated freeze | |||
N | value | N | value | |
Fluoroscopy time (min) | 1700 | 16.6 ± 7.5 | 1393 | 22.3 ± 9.7 |
Procedure time (min) | 1700 | 90.5 ± 27.0 | 1393 | 122 ± 35.2 |
Periprocedural death | 1735 | 1 (0.06) | 1428 | 0 (0.00) |
Periprocedural stroke or TIA | 1735 | 7 (0.40) | 1428 | 3 (0.21) |
Tamponade | 1735 | 2 (0.12) | 1428 | 4 (0.28) |
Atrio-oesophageal fistula | 1735 | 0 (0.00) | 1428 | 0 (0.0) |
. | Overall . | |||
---|---|---|---|---|
. | N . | Value . | ||
Age (years) | 3163 | 61.3 ± 10.8 | ||
Male sex | 3163 | 2025 (64.0) | ||
Paroxysmal AF | 3163 | 2261 (71.5) | ||
CHA2DS2-VASC score | 2069 | 1.3 ± 0.90 | ||
BMI (kg/m2) | 2339 | 28.0 ± 5.3 | ||
Left atrial diameter (mm) | 2818 | 42.7 ± 6.9 | ||
Single freeze | Repeated freeze | |||
N | value | N | value | |
Fluoroscopy time (min) | 1700 | 16.6 ± 7.5 | 1393 | 22.3 ± 9.7 |
Procedure time (min) | 1700 | 90.5 ± 27.0 | 1393 | 122 ± 35.2 |
Periprocedural death | 1735 | 1 (0.06) | 1428 | 0 (0.00) |
Periprocedural stroke or TIA | 1735 | 7 (0.40) | 1428 | 3 (0.21) |
Tamponade | 1735 | 2 (0.12) | 1428 | 4 (0.28) |
Atrio-oesophageal fistula | 1735 | 0 (0.00) | 1428 | 0 (0.0) |
. | Overall . | |||
---|---|---|---|---|
. | N . | Value . | ||
Age (years) | 3163 | 61.3 ± 10.8 | ||
Male sex | 3163 | 2025 (64.0) | ||
Paroxysmal AF | 3163 | 2261 (71.5) | ||
CHA2DS2-VASC score | 2069 | 1.3 ± 0.90 | ||
BMI (kg/m2) | 2339 | 28.0 ± 5.3 | ||
Left atrial diameter (mm) | 2818 | 42.7 ± 6.9 | ||
Single freeze | Repeated freeze | |||
N | value | N | value | |
Fluoroscopy time (min) | 1700 | 16.6 ± 7.5 | 1393 | 22.3 ± 9.7 |
Procedure time (min) | 1700 | 90.5 ± 27.0 | 1393 | 122 ± 35.2 |
Periprocedural death | 1735 | 1 (0.06) | 1428 | 0 (0.00) |
Periprocedural stroke or TIA | 1735 | 7 (0.40) | 1428 | 3 (0.21) |
Tamponade | 1735 | 2 (0.12) | 1428 | 4 (0.28) |
Atrio-oesophageal fistula | 1735 | 0 (0.00) | 1428 | 0 (0.0) |
. | Overall . | |||
---|---|---|---|---|
. | N . | Value . | ||
Age (years) | 3163 | 61.3 ± 10.8 | ||
Male sex | 3163 | 2025 (64.0) | ||
Paroxysmal AF | 3163 | 2261 (71.5) | ||
CHA2DS2-VASC score | 2069 | 1.3 ± 0.90 | ||
BMI (kg/m2) | 2339 | 28.0 ± 5.3 | ||
Left atrial diameter (mm) | 2818 | 42.7 ± 6.9 | ||
Single freeze | Repeated freeze | |||
N | value | N | value | |
Fluoroscopy time (min) | 1700 | 16.6 ± 7.5 | 1393 | 22.3 ± 9.7 |
Procedure time (min) | 1700 | 90.5 ± 27.0 | 1393 | 122 ± 35.2 |
Periprocedural death | 1735 | 1 (0.06) | 1428 | 0 (0.00) |
Periprocedural stroke or TIA | 1735 | 7 (0.40) | 1428 | 3 (0.21) |
Tamponade | 1735 | 2 (0.12) | 1428 | 4 (0.28) |
Atrio-oesophageal fistula | 1735 | 0 (0.00) | 1428 | 0 (0.0) |
Discussion
The main findings of this systematic review are: (i) a single freeze cryoballoon ablation is as effective as a bonus/double-freeze strategy, while (ii) associating with a lower risk of adverse events (with a strong trend for lower risk of persistent PNP) and (iii) a shorter procedure duration. These findings question the need for routine bonus freeze and suggest that a single freeze strategy should be the preferred technique for cryoballoon ablation of AF.
Cryoballoon ablation is widely considered as equivalent to RFA of AF in terms of efficacy.1,7,8 Recent publications indicate that AF ablation using the cryoballoon might become the first-line treatment of choice for patients with paroxysmal AF as it is more effective than antiarrhythmic drug therapy.14,15 However, in these multicentre RCTs, the cryoballoon ablation was routinely conducted using a double freeze strategy.
A growing body of evidence suggests the possibility of reducing the number of freezes to shorten the procedure and lower the risk of persistent PNP, a relatively common complication of cryoballoon ablation, without compromising the long-term effectiveness.11,12,21 This systematic review and meta-analysis summarizes the current knowledge on the effectiveness and safety of the cryoballoon ablation single freeze strategy. Included studies had good overall quality and described similar cryoballoon ablation techniques, had mandatory confirmation of pulmonary vein isolation, and used relatively homogeneous definitions of effectiveness, safety outcomes, and follow-up methods, which adds credence to the results. We highlight that patients included in these studies were relatively healthy, with a low average CHA2DS2-VASc score and predominantly with paroxysmal AF, and therefore it is unclear whether our results can be extrapolated to cohorts of persistent AF patients.
In terms of effectiveness, none of the individual studies reported a significant difference between strategies, yet the pooled analysis as well as the subgroup analysis based on study design confirmed that a single freeze strategy is as effective as using a routine bonus freeze (Figures 2 and 3). Simultaneously, the single-freeze strategy was associated with a lower risk of adverse events, which was seen in both RCTs and non-RCTs and was largely driven by a borderline significant reduction in persistent PNPs (Figures 2B and 3A). Given that this lower risk of adverse events was seen consistently across studies, with no significant heterogeneity between studies or evidence of significant publication bias, it reinforces the idea that adding a routine second freeze may be deleterious and should not be generally pursued. The single freeze procedures were also on average 20 min shorter, which may be useful to improve EP lab workflow without compromising patient safety and treatment efficacy.
This systematic review does not, however, provide any indications for the optimal technique for a single cryoballoon application. Included studies differed in terms of utilization of TTI guidance or length of cryoballoon applications—180/240 s in general (Table 1). However, due to occasionally short TTI, the total application times may have been even lower than 180 s in selected cases.22,25,31 It must be emphasized that studies using TTI-guided cryoablation had a formal protocol for quality control of the lesion formation which anticipated prolongation of the application based on prespecified TTI thresholds.10,11,21,22,25,26,31 Still, there was virtually no heterogeneity between studies in terms of effectiveness and safety regardless of the technique used during the single freeze strategy (Figure 2). While the influence of the length of cryoballoon application on the long-term effectiveness of AF ablation was clearly beyond the scope of this review, it should be bore in mind that there is evidence suggesting a significant association between longer freeze times and better rate of durable pulmonary vein isolation.32
Although the results of this systematic review and meta-analysis support the use of a single freeze strategy, our findings must be interpreted in the broader setting and should also take into account the data obtained at the time of re-do ablation in patients with recurrent AF.32–36 Published data suggest that gaps identified during re-do AF procedures after initial cryoballoon ablations tend to accumulate in the vicinity of the left atrial appendage/left superior pulmonary vein ridge, the superior aspect of right superior and inferior aspect of right inferior pulmonary veins. While we could argue that additional ‘bonus’ freezes in those areas may improve durability of cryoballoon-derived pulmonary vein isolation, the present meta-analysis suggests that additional applications in the vicinity of the right pulmonary veins should be discouraged and operators should instead take time to properly position the cryoballoon so it achieves optimal occlusion at the time of the first lesion. As far as the left pulmonary veins are concerned, the potential for fistula formation associated with very low temperatures and repeat freezes, especially in the inferior vein, has been previously reported.37 Our study does not support the need for routine bonus freeze in this area.
Limitations
This study has the typical limitations of systematic reviews and meta-analyses. Most of the included studies were observational and, although these were generally of good quality, they cannot replace large scale RCTs. However, our results were consistent across RCTs and non-RCTs, which adds robustness to our findings. In addition, where non-randomized studies are concerned, a learning curve effect cannot entirely be ruled out; some studies noted that a single-freeze strategy was adopted later than a double-freeze strategy. However, this notion is not supported by outcomes of included randomized trials which were all conducted by experienced investigators and generally reported similar effectiveness and safety to observational studies. High heterogeneity in terms of procedure duration (I2 = 96%) does not allow to consider the calculated difference of 20 min fully conclusive. However, all but one RCT and two observational studies reported that the time of single freeze procedure was significantly shorter than the double-freeze.
Conclusion
A single freeze strategy for cryoballoon ablation of AF is as effective as an empiric double (‘bonus’) freeze strategy while appearing safer and probably quicker (PROSPERO registration number CRD42020158696).
Supplementary material
Supplementary material is available at Europace online.
Conflict of interest: M.M.F. and M.P. received speaker/proctoring fees from Abbott Medical Poland, Medtronic Poland. S.B. received training grants from Biosense and Biotronik. D.G. holds shares in the company, which delivers consulting services to Abbott Medical Poland, Medtronic and Zoll. A.A. is a consultant for Farapulse Inc, Galaxy Medical Inc. A.A. received contracted research funds from Boston Scientific Inc, Farapulse Inc, Galaxy Medical Inc and Biosense&Webster. C.d.A. receive compensation for teaching purposes and proctoring from AF solutions, Medtronic, Abbott, Biotronik, Atricure, Boston Scientific, Microport, Acutus, Biosense Webster, Daiichi Sankyo, Schwarzer Cardiotek GmbH, and research grants on behalf of the centre from Biotronik, Medtronic, Abbott, Microport, Boston Scientific, Biosense Webster, Daiichi Sankyo, Atricure, Schwarzer Cardiotek GmbH Boehringer Ingeheim, BMS/Pfizer. D.A.L. received investigator-initiated educational grants from Bristol-Myers Squibb (BMS), speaker fees from Boehringer Ingeheim and BMS/Pfizer and consultancy from BMS/Pfizer, Boehringer Ingelheim, and Daiichi-Sankyo. S.Bo. is consultant for Medtronic, Boston Scientific, Microport and Zoll.
Acknowledgements
The production of this document is under the responsibility of the Scientific Initiatives Committee of the European Heart Rhythm Association: Serge Boveda (Chair), Giulio Conte (Co-Chair), Ante Anic, Sergio Barra, Julian K.R. Chun, Carlo de Asmundis, Nikolaos Dagres, Michal M. Farkowski, Jose Guerra, Konstantinos E. Iliodromitis, Kristine Jubele, Jedrzej Kosiuk, Eloi Marijon, Rui Providencia, Frits Prinzen.